common

S-XL Low Voltage Panel Distribution Box Distribution Board, Cabinets

Stable energy supply: supply and distribute electric energy to electrical equipment, providing safe and stable power supply.

Safe start and stop of equipment: start and stop electrical equipment through start and stop buttons, operating switches, handles, etc., to provide safety protection for the equipment.

Detection and monitoring: through transformers, power meters and other equipment, effective monitoring of power distribution equipment is achieved.

Safety protection: provide diversified safety protection such as overcurrent protection, overload protection, overload protection, leakage current protection, etc.

  • Item NO. :

    S-XL
  • Certificate :

    CQC
  • Lead time :

    25 Days
  • Payment :

    T/T
  • MOQ :

    ≥1
  • Warranty :

    1 Year

 

S-XL Power Distribution Cabinet Box

 

Enecell is Low Voltage Power Distribution Cabinets Manufacturer and Power Distribution Cabinets Supplier, The S-XL low-voltage power distribution cabinet box is suitable for power distribution in power plants and industrial and mining enterprises in three-phase four-wire or three-phase five-wire systems with AC voltages of 500 volts and below. The S-XL low-voltage power distribution box is an indoor device installed against the wall and inspected in front of the screen.

Low voltage Distribution Boards complies with relevant standards such as IEC60439-1 and GB7251.1 "Low-voltage complete switch gear and control equipment".

 

Product Overview


LXL low-voltage power distribution box is suitable for three-phase four-wire or three-phase five-wire power systems with AC 50Hz and rated working voltage of 660V and below in industrial and civil buildings, and is used for power distribution and lighting distribution.

 

Product model meaning

 

 

Normal use environment conditions

 

1. The ambient air temperature is not higher than +40℃, not lower than -5℃, and its average temperature within 24 hours is not higher than +35℃. The equipment should be used at reduced capacity when it exceeds the above environment.

2. The relative humidity does not exceed 50% when the maximum temperature is +40℃. A higher relative humidity is allowed at a lower temperature, such as 90% at +20℃. The influence of condensation that may occur accidentally due to temperature changes should be considered.

3. The installation site is usually installed at an altitude of no more than 2000m. For places above 2000m, the capacity should be reduced accordingly.

4. Install in places without fire, explosion hazard, severe dust, chemical corrosion, severe vibration and impact.

5. If the above conditions cannot be met, the user and the manufacturer should negotiate to resolve.

 

Main technical parameters

 

Serial number

Project

Parameter

1

Rated insulation voltage 500V/660V (1000V)/AC

2

Rated working voltage 220V/380V (660V)/AC

3

Over voltage level

4

Pollution level 3

5

Rated frequency 50Hz

6

Rated current

up to 630A

7

Rated short-time withstand current

up to 15kA

8

Rated peak withstand current up to 30kA

9

Protection level

IP40 to IP54

10

Equipment height 1600, 1800mm

11

Equipment width

600, 700, 800mm

12

Equipment depth

350, 450mm

 

Note: Other structural dimensions can be customized according to customer requirements.

 

Structural features

 

1. This product has a closed structure and can be installed on the wall, operated and maintained from the front; it can also be installed away from the wall, operated from the front, and maintained from both sides.

2. The box is made of high-quality cold-rolled steel plates bent and welded, with high mechanical strength and good overall performance; stainless steel products can also be provided according to customer needs.

3. The front door is connected to the box with multiple strands of soft copper wire to form a complete grounding protection circuit.

4. The surface of the box adopts high-voltage electrostatic spraying technology, which has strong adhesion, good texture, beautiful and durable.

5. The four corners of the top of the box are equipped with lifting rings for lifting and shipping.

6. The protection level of the box is IP40, and it can be selected between IP20 and IP54 according to the user's installation site requirements.

7. The box can be used alone or in multiple units, with the characteristics of flexible installation, simple operation, and convenient maintenance.

 

 

Appearance diagram

 

 

Equipment installation dimensions

Overall dimensions(mm) Installation dimensions(mm)
Width Depth A B
600 350 460 300
600 450 460 400
700 350 560 300
700 450 560 400
800 350 660 300
800 450 660 400

 

Ordering Instructions


When ordering, users should provide the following information:
1. Feng circuit scheme diagram and primary system diagram.
2. Auxiliary circuit electrical schematic diagram and terminal arrangement diagram. If there is no schematic diagram and terminal arrangement diagram, follow the manufacturer's standard.
3. Equipment arrangement and combination diagram and floor plan.
4. Model, specification and quantity of main electrical components in the equipment.
5. Inlet and outlet line mode and cable specifications. If busbar connection is required between equipment or incoming line unit, busbar span, height from the ground and other data should be provided.
6. Surface color of the equipment.
7. Other special requirements should be negotiated with the manufacturer.

 

Ordering Instructions

 

When ordering, users should provide the following information:
1. Schematic diagram of Feng circuit, primary system diagram.
2. Auxiliary circuit electrical schematic diagram, terminal arrangement diagram. If there is no schematic diagram and terminal arrangement diagram, follow the manufacturer's standards.
3. Equipment layout combination diagram, plane layout diagram.
4. Model, specification, and quantity of main electrical components in the equipment.
5. Inlet and outlet line mode, cable specifications. If busbar connection is required between equipment rooms or incoming line units, data such as busbar span and height from the ground should be provided.
6. Equipment surface color.
7. Other special requirements should be negotiated with the manufacturer.

 

 

Product Picture

 

 

Application Case

 

Nanjing Zhonggui Pharmaceutical Smart Factory Project
Guangzhou Nanpingshan Second Village Economic Development Zone Project
Shunde Shenghui Holdings Headquarters Park
Qingzhou Museum New Building Intelligentization Project
Dongguan China-Israel International Science and Technology Cooperation Industrial Center
Zhengzhou Tianqin Bay Project
Dongguan Country Garden Vientiane Songhu Phase IV
Putian Helenberg Jiuyuefu Project
Baoneng City Garden Project
Country Garden Zhengyang Park Phase I Project

 

Warehouse Real Scene

 

 

Generate Workshop

 

 

Product Packaging

 

 

 

Request a Quote
Welcome to contact us for quotation, All fields marked with an asterisk* are required.
Submit

Related Products

Can't Find Target Products? contact us!
#

Can't Find Target Products? contact us!

As a seasoned solar product manufacturer with over 15 years of manufacturing experience, Enecell has extensive experience in one-stop solar solutions to help clients offer applicable solar solution.
Customize Now!

Need Help? Chat with us

Request a Quote
Welcome to contact us for quotation, All fields marked with an asterisk* are required.
Submit

Home

Products

whatsApp

contact